The amount of solar panels and accumulators you need is more.
Accumulator to solar panel ratio factorio.
With 11k accumulators i get about 75 drain.
The ratio doesn t matter nearly as much as people seem to think it does.
During daylight hours every panel provides the maximum power level 60kw.
If your batteries can t fully charge during the day build more solar.
Generated power will increase decrease linearly during dusk and dawn and no power is produced at night.
Or we can say we need 21 25 0 84 accumulators per solar panel.
Night solar panels are producing 50 nominal power 40 of the day.
So for 2 1mw this works out to 50 solar panels and 42 accumulators exactly.
Or we can say we need 25 solar panels per 21 accumulators.
If connected to a circuit network an accumulator will output its level of charge as an integer from 0 to 100 to a specified signal.
Solar panels and accumulators optimal ratio.
9 100 solar panels vs 0 8 ratio 7 280 accumulators would that power my factory overnight.
But i can only afford to lose 25 of my accumulators based on current usage which means that a ratio of 0 8 accumulators to 1 solar.
Then when both of those are met build some more.
500 21 p mw solar panels 20 p mw accumulators these are the numbers i use.
Solar panels are an unlimited source of free energy that produce no pollution.
8571 3 7 kw solar panels 600 mj capacity of accumulators so the result is we need 25 21 1 190476 period 6 more solar panels than accumulators.
The accumulator stores a limited amount of energy when available production exceeds demand and releases it in the opposite case.
If you use the layout shown in katherine s guide and other places this utilises 180 solar panels and 151 accumulators to provide approximately 10mw per block day and night.
Dusk dawn so on average they produce 70 of nominal power.
Solar panels are producing 0 nominal power 10 of the day.
While the sun is out your solar panels have to output q power where q p.
Now you have enough for a while.
If they don t last the night build more batteries.
Its maximum charge discharge rate is 300 kw.
So the op post is 100 accurate.
This means one solar panel produces an average of 42 kw over one day and night cycle.
Your solar panels have 2 functions.
7 280 accumulators is 66 of my current amount.
The optimal ratio is 0 84 21 25 accumulators per solar panel and 23 8 solar panels per megawatt required by your factory this ratio accounts for solar panels needed to charge the accumulators this means that you need 1 428 mw of production of solar panels and 100mj of storage to provide 1 mw of power over one day night cycle.
Alternatively this works out to a ratio of 25 solar panels to 21 accumulators.
The correct ratio is 0 84 so 100 panels 84 accumulators will keep 24 hour supply of the appropriate power.